CNG reducer for sequential injection system.
CNG pressure reducer for sequential injection systems with inlet integrated high pressure solenoid valve. The CNG reducer adjustable outlet pressure allows to always get the best performance.
Available for 3 and 4 cylinder vehicles (including turbo engines), it meets the management needs of the latest generation engines by meeting the emission standards (Euro 6).
The OBDII connection offers a complete and accurate diagnostics of the gas system.
Homologation | ECE 67R-01 / ECE R110 / ECE 10R-03 |
Supply Voltage | 10 - 16 Volts CC |
Working temperature | -20 / + 120 °C |
Current absorbed stand-by (key off) | < 20 mA |
Current absorbed no loads (key on) | < 160 mA |
Lock-off load on single input | 2 (Imax = 4A) |
Inputs lock-off services | 2 |
Water/gas temp. sensors managed | 4,7 - 10 kOhm |
LPG/CNG level sensors managed | 0..5 V 1050 1090 110..0 Ohm 806 |
Managed Lambda Sensor | 0-0,8 0-5 5-0 0,8-1,6 2,5-3,5 UEGO |
OBD standard managed | ISO 9141-2 KEYWORD 2000 (5 BAUD and INIT FAST) CAN STANDARD 250 CAN STANDARD 500 CAN EXTENDED 250 CAN EXTENDED 500 |